Hvac — problems, causes and costs
I Like To Fix
Everything we have on hvac — what fails, why, what it costs, and which of it you can handle without calling anyone.
Homes built before about 1940
Pre-war construction — galvanized supply, cast iron drains, cloth-wrapped wiring, ungrounded circuits.
- Ductwork threaded through a house built for floor grates
- One central return for the whole house
- Water heater vents into the chimney and the furnace no longer does
- Silver-wrapped tape on old duct joints
- Additions still on window units
- Uninsulated walls and an oversized condenser
- Furnace runs but the house never warms evenly
- Electrical panel cannot support a modern condenser
- Filter slot is a gap behind a grille
Homes built roughly 1940 to 1980
Post-war and mid-century — copper supply, aging cast iron stacks, 60 to 100 amp panels, first-generation central air.
- R-22 system leaking refrigerant
- Rust or soot streaks at the furnace heat exchanger
- Ducts in an unconditioned attic
- Thermostat has only four wires
- Condenser pad has sunk and the unit leans
- System cools but the house stays humid
- Evaporator coil freezing over
- Only some rooms cool, and always the same ones
- Blower runs constantly and never satisfies
Homes built roughly 1980 to 2000
The polybutylene and aluminum-wiring window, 150 amp panels, R-22 systems and first-cycle architectural shingle.
- SEER 10 system still running at thirty years
- Flex duct crushed or kinked in the attic
- Water on the floor near the air handler
- Cooling drops off on the hottest days only
- One zone stuck hot or cold
- Squeal or grind from the air handler
- Refrigerant line insulation crumbling
- Outdoor unit caked in cottonwood and red dust
- Thermostat set to 72 and the house reads 78
Homes built since 2000
PEX on slab, 200 amp service, builder-grade equipment that reaches end of life across a whole street at once.
- Whole street replacing systems the same year
- Upstairs runs hot no matter the setting
- Control board fault on a communicating system
- Smart thermostat installed and the heat now runs oddly
- Condensate pump buzzing or backing up
- White PVC vent pipes outside stained or dripping
- House feels stuffy in a new build
- Fifteen degree difference between floors
- Loud startup thump from the outdoor unit
Any age of home
- Furnace ignites, runs a minute, shuts off
- Gas smell near the furnace
- Heat pump runs constantly below freezing
- Outdoor unit steaming in winter
- Dual fuel system switching at the wrong temperature