Aluminum branch wiring
I Like To Fix
Solid aluminum branch circuit wiring was used in homes from roughly 1965 to 1973 and the Consumer Product Safety Commission has identified it as a fire hazard. The problem is at the connections rather than in the wire – aluminum expands, contracts and oxidizes, and terminations loosen and overheat. The accepted repairs are COPALUM crimps or AlumiConn connectors at every device. Pigtailing with ordinary wire nuts is not an approved fix and is still commonly sold as one.